::Mirage Panel
Links |
This Is Page 3 Mirage Accessories, Section Properties and Load Tables | ||||||||||||||||||||||||||||||||||||||||||||||||||||
::
Page 1 |
Mirage is a concealed fastener metal roofing roofing
panel that is ideal for commercial, industrial, and architectural applications.
Mirage panels feature 1 5/8” ribs spaced 8” on center.
The end result is an aesthetically pleasing roof that will add beauty and elegance to most any project. Mirage panels are installed over solid decking or substructural members utilizing concealed clips. Mirage is available with a Galvalume substrate and a variety of Kynar 500®/Hylar 5000™ colors. |
||||||||||||||||||||||||||||||||||||||||||||||||||||
| Main Site Links | |||||||||||||||||||||||||||||||||||||||||||||||||||||
| :: Standing seam roofing | |||||||||||||||||||||||||||||||||||||||||||||||||||||
| :: Maxima :: Medallion-Lok :: Medallion I :: Medallion II :: Meridian :: Mirage :: MasterLok-90 |
Maxima Section Properties |
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
| :: Exposed Fastener Panels | |||||||||||||||||||||||||||||||||||||||||||||||||||||
| :: Mega Rib :: Multi Rib :: Max-Rib :: Mac-Rib :: 5V Crimp Panel :: "U" Panel :: Multi-Cor :: M-Cor |
|||||||||||||||||||||||||||||||||||||||||||||||||||||
| :: Wall Panels | |||||||||||||||||||||||||||||||||||||||||||||||||||||
| Mirage Accessories And Pricing Information | |||||||||||||||||||||||||||||||||||||||||||||||||||||
| ::
Multi-V :: R-Panel |
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||
| :: Soffit and Liner Panel | |||||||||||||||||||||||||||||||||||||||||||||||||||||
| ::
Marquee
II :: Mini-Rib |
|||||||||||||||||||||||||||||||||||||||||||||||||||||
| :: Modular Metal Buildings | |||||||||||||||||||||||||||||||||||||||||||||||||||||
| :: Modular Storage System | ![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||||
Didn't find what you're looking for here? Visit our website totally dedicated to metal roofing. Five different major metal roofing manufacturers - www.BetterBuiltMetal.com |
|||||||||||||||||||||||||||||||||||||||||||||||||||||
| Mirage- Section Properties | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Notes *Section properties are calculated
in accordance with the 1986 Edition of the Cold Formed Steel Design Manual. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Better Built, Inc. doesn't just sell and McElroy Metal. We also sell metal buildings: Full metal, hybrids and postframe of all types - Pole Barns, Horse Barns, Gazebos, Pavillions, Storage Facilities, Churches, Storefronts, Carports, Additions and Agricultural Buildings of any sort. Better Built, Inc. is also a proud distributor of the following building products: Alside Premium Vinyl Siding, Clopay Residential Garage Doors and Commercial Doors, Priefert Ranch Equipment, Janus Rollup Doors, Croft Vinyl and Extruded Aluminum Windows and Prodex High-R Insulation. So come check out the best of the best buildings and building products at www.getbetterbuilt.com.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
| Mirage- Section Properties | |||||||||||||||||||||||||||||||||||||||||||||||||||||
| Better Built Metal Sales | Top In Compression | Bottom In Compression | |||||||||||||||||||||||||||||||||||||||||||||||||||
| Panel Width | Panel Gauge | Weight PSF |
FY KSI |
Ix IN.4 |
Se IN.3 |
Ma KIP IN. |
Ix IN.4 |
Se IN.3 |
Ma KIP IN. |
||||||||||||||||||||||||||||||||||||||||||||
| 16" | 24 | 1.38 | 50.0 | .1038 | .0808 | 2.4190 | .0654 | .0730 | 2.1840 | ||||||||||||||||||||||||||||||||||||||||||||
| Mirage - Load Table | |||||||||||||||||||||||||||||||||||||||||||||||||||||
| Allowable Loads (PSF)* | <----------- Positive Wind Load ---------> | ||||||||||||||||||||||||||||||||||||||||||||||||||||
| Ga. | Span Type | 3 | 4 | 5 | 6 | 7' | 8' | ||||||||||||||||||||||||||||||||||||||||||||||
| 24 | 3 Span | 270 | 152 | 97 | 67 | 50 | 38 | ||||||||||||||||||||||||||||||||||||||||||||||
| Allowable Loads (PSF)* | <--------- Live Load --------> | ||||||||||||||||||||||||||||||||||||||||||||||||||||
| Ga. | Span Type | 3 | 4 | 5 | 6 | 7' | 8' | ||||||||||||||||||||||||||||||||||||||||||||||
| 24 | 3 Span | 202 | 114 | 73 | 51 | 37 | 28 | ||||||||||||||||||||||||||||||||||||||||||||||
| Notes | |||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1) Allowable uniform loads
are based upon 3 equal span lengths and are calculated in accordance with
the sound engineering principles and practices using the given section properties. 2) Wind Load is wind section or uplift and is based upon ASTM E 1592 test data using a factor of safety of 1.65. 3) Wind Load has been increased by 3 1/3%. (Note: Increase is not allowed on military projects.) 3) Deflection loads are limited by a maximum deflection of L/80 or the maximum bending stress whichever is less. 5) Live Load is the allowable Live or Snow Load. 6) The weight of the panel has not been deducted from the allowable loads. 7) Web crippling has not been checked for the allowable loads shown above. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||
Discount Pricing ::
Contractor
Discount Pricing ::
Preferred
Internet Customer Pricing |
|||||||||||||||||||||||||||||||||||||||||||||||||||||
| Copyright
© 2005 Better Built Buildings, Inc. 1284 Jackson Avenue -
Chipley, Florida (850) 415-1998 Fax: (850) 415-1996 Copyright 2005, All Rights Reserved Better Built Buildings, Inc. Email: gotmetal@bellsouth.net |
|||||||||||||||||||||||||||||||||||||||||||||||||||||
| Website Created and Maintained by ProductionAnimal.com | |||||||||||||||||||||||||||||||||||||||||||||||||||||