::Multi-Rib-R-Panel-Multi-V
Panels Links |
This Is Page 4 Metal Roofing Multi-Rib / R-Panel / Multi-V Section Properties & Load Tables | ||||||||||||||||||||
:: Page
1 General Information |
Multi-Rib is one of the most versatile members of the
McElroy family of quality products that we
sell. It is truly a multi-use wall and
roof panel whose applications span a tremendous variety of commercial
and industrial construction projects.
Multi-Rib’s superiority as a metal roofing panel is proven
by compliance with the rigid Underwriters’ Laboratories UL-90 wind uplift
test, ASTM E1680 air infiltration, ASTM E1646 water infiltration testing
and UL 2218 Class 4 impact resistance test. |
||||||||||||||||||||
| Main Site Links | |||||||||||||||||||||
| :: Standing seam roofing | |||||||||||||||||||||
| :: Maxima :: Medallion-Lok :: Medallion I :: Medallion II :: Meridian :: Mirage :: MasterLok-90 |
|||||||||||||||||||||
| Multi-Rib / R-Panel / Multi-V Section Properties | |||||||||||||||||||||
| :: Exposed Fastener Panels | ![]() |
![]() |
![]() |
||||||||||||||||||
| :: Mega Rib :: Multi Rib :: Max-Rib :: Mac-Rib :: 5V Crimp Panel :: "U" Panel :: Multi-Cor :: M-Cor |
|||||||||||||||||||||
Multi-Rib - Section Properties |
|||||||||||||||||||||
| :: Wall Panels | |||||||||||||||||||||
Better Built Metal Sales |
Top In Compression | Bottom In Compression | |||||||||||||||||||
| ::
Multi-V :: R-Panel |
|||||||||||||||||||||
| Panel Gauge |
Weight PSF |
FT KSI |
Ix IN.4 |
Se IN.3 |
MA KIP IN. | Ix IN.4 |
Se IN.3 |
Ma KIP IN. | |||||||||||||
| :: Soffit and Liner Panel | |||||||||||||||||||||
| ::
Marquee
II :: Mini-Rib |
29 | 0.75 | 80 | .0217 | .0201 | 0.965 | .0145 | .0214 | 1.024 | ||||||||||||
| 26 | 0.95 | 80 | .0326 | .0309 | 1.482 | .0198 | .0300 | 1.435 | |||||||||||||
| :: Modular Metal Buildings | |||||||||||||||||||||
| 26 | 0.95 | 50 | .0365 | .0371 | 1.112 | .0213 | .0332 | .0995 | |||||||||||||
| :: Modular Storage System | |||||||||||||||||||||
| 24 | 1.20 | 80 | .0454 | .0460 | 2.205 | .0265 | .0411 | 1.970 | |||||||||||||
![]() |
|||||||||||||||||||||
| 24 | 1.20 | 50 | .0486 | .0499 | 1.494 | .0286 | .0462 | 1.382 | |||||||||||||
| R-Panel - Section Properties | |||||||||||||||||||||
| Better Built Metal Sales | Top In Compression | Bottom In Compression | |||||||||||||||||||
![]() |
Panel Gauge |
Weight PSF |
FT KSI |
Ix IN.4 |
Se IN.3 |
MA KIP IN. | Ix IN.4 |
Se IN.3 |
Ma KIP IN. | ||||||||||||
| 29 | 0.69 | 80 | .0247 | .0219 | .7883 | .0242 | .0301 | 1.082 | |||||||||||||
| 26 | 0.88 | 80 | .0371 | .0337 | 1.211 | .0349 | .0400 | 1.437 | |||||||||||||
| 26 | 0.88 | 50 | .0394 | .0362 | 1.085 | .0361 | .0405 | 1.211 | |||||||||||||
Didn't find what you're looking for here? Visit our website totally dedicated to metal roofing. Five different major metal roofing manufacturers - www.BetterBuiltMetal.com |
|||||||||||||||||||||
| 24 | 1.04 | 80 | .0454 | .0460 | 1.664 | .0444 | .0486 | 1.746 | |||||||||||||
| 24 | 1.04 | 50 | .0474 | .0482 | 1.442 | .0457 | .0491 | 1.469 | |||||||||||||
| Multi-V - Section Properties | |||||||||||||||||||||
| Better Built Metal Sales | Top In Compression | Bottom In Compression | |||||||||||||||||||
| Panel Gauge |
Weight PSF |
FT KSI |
Ix IN.4 |
Se IN.3 |
MA KIP IN. | Ix IN.4 |
Se IN.3 |
Ma KIP IN. | |||||||||||||
| 29 | 0.72 | 80 | .0125 | .0226 | 1.084 | .0168 | .0231 | 1.100 | |||||||||||||
| 26 | 0.93 | 80 | .0170 | .0297 | 1.424 | .0236 | .0309 | 1.461 | |||||||||||||
| 26 | 0.02 | 50 | .0183 | .0331 | 0.991 | .0236 | .0326 | 0.975 | |||||||||||||
| 24 | 1.15 | 80 | .0220 | .0412 | 0.975 | .0304 | .0405 | 1.942 | |||||||||||||
| 24 | 1.15 | 50 | .0242 | .0475 | 1.422 | .0304 | .0426 | 1.276 | |||||||||||||
| Notes | |||||||||||||||||||||
Better Built, Inc. doesn't just sell and McElroy Metal. We also sell metal buildings: Full metal, hybrids and postframe of all types - Pole Barns, Horse Barns, Gazebos, Pavillions, Storage Facilities, Churches, Storefronts, Carports, Additions and Agricultural Buildings of any sort. Better Built, Inc. is also a proud distributor of the following building products: Alside Premium Vinyl Siding, Clopay Residential Garage Doors and Commercial Doors, Priefert Ranch Equipment, Janus Rollup Doors, Croft Vinyl and Extruded Aluminum Windows and Prodex High-R Insulation. So come check out the best of the best buildings and building products at www.getbetterbuilt.com. |
|||||||||||||||||||||
1)
Section properties are calculated in accordance with the 1986 Edition
of the Cold Formed Steel Design Manual. 2) Ix is for deflection determination. 3) Se is for bending. 4) Ma is the allowable bending moment. 5) All values are for the foot of panel width. |
|||||||||||||||||||||
| Foot Notes: (PSF) Oil caning is a natural occurrence in metal panels and is not a cause for panel rejection. |
|||||||||||||||||||||
| Multi-V Load Tables | |||||||||||||||||||||
| Allowable Loads (PSF)* | <--------- Positive Wind Load --------> | ||||||||||||||||||||
| Ga. | FY RSI | 3' | 4' | 5' | 6' | 7' | 8' | ||||||||||||||
| 29 | 80 | 137 | 76 | 39 | 22 | 14 | 9 | ||||||||||||||
| 26 | 80 | 183 | 103 | 52 | 30 | 19 | 13 | ||||||||||||||
| 26 | 50 | 120 | 68 | 43 | 30 | 20 | 13 | ||||||||||||||
| 24 | 80 | 240 | 135 | 69 | 40 | 25 | 17 | ||||||||||||||
| 24 | 50 | 158 | 89 | 57 | 39 | 26 | 18 | ||||||||||||||
| Allowable Loads (PSF)* | <--------- Live Load --------> | ||||||||||||||||||||
| Ga. | FY RSI | 3' | 4' | 5' | 6' | 7' | 8' | ||||||||||||||
| 29 | 80 | .23 | .40 | .50 | .60 | .70 | .80 | ||||||||||||||
| 26 | 80 | .23 | .40 | .50 | .60 | .70 | .80 | ||||||||||||||
| 26 | 50 | .14 | .25 | .39 | .57 | .70 | .80 | ||||||||||||||
| 24 | 80 | .22 | .40 | .50 | .60 | .70 | .80 | ||||||||||||||
| 24 | 50 | .14 | .25 | .39 | .57 | .70 | .80 | ||||||||||||||
| Notes | |||||||||||||||||||||
1) Allowable uniform loads are based upon
equal span lengths. 2) Positive wind is wind pressure and is increased by 33 1/3% 3) Negative wind is wind suction or uplift and is increased by 33 1/3% 4) Live is the allowable live or snow load. 5) Deflection (L/180) is the allowable load that limits the panels deflection to L/240. 6) Deflection (L/240) is the allowable load that limits the panels deflection to L/240. 7) The weight of the panel has not been deducted from the allowable loads. 8) Web crippling has not been checked for the allowable loads shown above. |
|||||||||||||||||||||
Foot Notes:
(PSF) *Oil caning is a natural occurrence in metal panels and is not a cause for panel rejection. |
|||||||||||||||||||||
Discount Pricing ::
Contractor
Discount Pricing ::
Preferred
Internet Customer Pricing |
|||||||||||||||||||||
| Copyright
© 2005 Better Built Buildings, Inc. 1284 Jackson Avenue -
Chipley, Florida (850) 415-1998 Fax: (850) 415-1996 Copyright 2005, All Rights Reserved Better Built Buildings, Inc. Email: gotmetal@bellsouth.net |
|||||||||||||||||||||
| Website Created and Maintained by ProductionAnimal.com | |||||||||||||||||||||